Setting The Data To Output Automatically After Measurements - Omron FQ2-S/CH Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Setting the Data to Output Automatically after Measurements

You can set the data to output automatically after measurements. (You can set up to 32 data items.)
Data That Can Be Output
• Data Output
On the FQ2, data output after measurement can be assigned to Data 0 to Data 31 in the output data settings.
The data of items assigned in the output data settings are output in units of 4 bytes per item.
The measurement data from inspection items that can be output and the calculation results from the
expression settings can be output. For data that can be output, refer to the Measurement Data That Can Be
Used for External Outputs and Calculations for each inspection item.
Assigning Inspection Results to Output Data: p. 176
Assigning More Than One Inspection Result to the Same Output Data: p. 176
• Character Output (Only Supported on the FQ2-S4/CH)
You can output a character string that contains up to 1,024 characters for each of the inspection item that reads
a character string, such as the OCR inspection item. Also, when reading the character string fails, you can
output a specific character string that is set in advance.
Outputting Read Character Strings: p. 181
FQ2-S/CH User's Manual
for Communications Settings
Control and Output in No-Protocol (TCP) / No-Protocol (UDP)
175