Command code in
command area (hex)
00102020
00102060
00103010
00104010
00104020
00104021
00104022
00104031
00104032
00108010
00108020
00109010
0010F010
Important
After you execute the Reset command (0010F010 hex) for the Sensor, turn OFF the EXE signal before the Sensor
restarts. If you leave the EXE signal ON, the Sensor will restart repeatedly.
162
Outputting Data and Controlling Operation through PROFINET
Command name
Clear Data Output Buffer
Clear Statistical Data
Save Data in Sensor
Re-register Model
(Search, Shape search III,
Shape search II, Sensitive
search, Color data)
Teaching
(All Inspection Items)
Teaching
(Filter/Position Compensation
Item)
Teaching
(Inspection Item)
Re-register Reference Value
(Position Compensation Item)
Re-register Reference Value
(Inspection Item)
Set Registered Image
Acquire Registered Image
Echo
Reset Sensor
Function
Clears all data in the data output buffer of the
Sensor.
Clears the statistical data (such as the num-
ber of measurements, the number of NG
overall judgments, the NG rate, and other
information since the power supply was
turned ON) produced by the logging function
held by the Sensor.
This command saves the current setting data
(system data, scene groups, and calibration
data) in the Sensor.
This command re-registers the models for
registered Search, Shape search III, Shape
search II, Sensitive search, and Color data
inspection items.
Executes teaching for all registered inspec-
tion items.
Updates reference data for the specified
image adjustment processing item (filter item/
position compensation item).
Updates the reference data for the specified
inspection item.
Re-registers the reference value for the spec-
ified position compensation item based on
the previously loaded image.
Re-registers the reference values for the
specified inspection item based on the previ-
ously loaded image.
Sets the latest image or a specified logging
image as a registered image.
Loads a registered image saved to the SD
card or PC Tool as the measurement image.
This command returns any data (32 bits or 2
words) sent by the external device as-is.
Restarts the Sensor.
Reference
p.217
p.218
p.218
p.219
p.219
p.220
p.221
p.221
p.222
p.223
p.224
p.225
p.225
FQ2-S/CH User's Manual