Parameter
Timeout
This parameter is displayed and can be set only
when [Output handshake] is set to [Yes].
A timeout error will occur if there is no response
from the external device within the time that is set.
• From when measurements are completed
until the DSA Bit turns ON
• From when the GATE flag turns ON until the
DSA Bit turns OFF
• From when the GATE flag turns OFF until the
DSA Bit turns ON
Data output period This parameter is displayed and can be set only
when [Output handshake] is set to [No]. Set the
period for outputting measurement results.
Important
Set a value that is longer that the GATE ON
output time and shorter than the measurement
interval of the Sensor.
GATE signal ON
This parameter is displayed and can be set only
period
when [Output handshake] is set to [No].
Set the time to turn ON the GATE signal.
Set the time that is required for the external
device to read the measurement results.
Important
Set a value which is equal or longer than the
[refreshing task period] (or the requested
packet interval).
FQ2-S/CH User's Manual
for Communications Settings
Description
Outputting Data and Controlling Operation through PROFINET
Setting range
0.1 to 120.0 s (default: 10.0 s)
2 to 5,000 ms (default: 40 ms)
1 to 1,000 ms (default: 20 ms)