<Execution command response format>
When the Command Is Processed Normally
Image data (binary)
CR
Delimiter
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Image data number
Image data size
Image data (binary)
PREALLIMAGESAVEB (Check) / ALLIMAGESAVEB (Execute)
Outputting all image (binary data)
This command outputs all images stored in the Sensor memory in binary format.
To execute this command, two types of commands are used, a confirmation command and an execution
command.
For how to execute the command using the confirmation command and the execution command, refer to
Binary Data File Load and Save Commands: p. 188.
<Confirmation command format>
Before all images saved to the Sensor's memory are output in binary data format, a check is performed to
determine if the data can be received by the external device that will receive the data.
P
R
E
A
L
<Confirmation command response format>
When the Command Is Processed Normally
CR
All image data size
Delimiter
O
K
CR
Delimiter
FQ2-S/CH User's Manual
for Communications Settings
Specifies the image data number (integer type) you want to output.
Specify 0 to 19.
Number of bytes of image data to output (integer type)
Image data to output (binary data)
L
I
M
A
G
E
S
A
V
E
B CR
Delimiter
385