Omron FQ2-S/CH Series User Manual page 281

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Save Statistical Data
Saves statistical data saved in the Sensor's memory by the logging function to the SD card inserted in the
Touch Finder as csv data.
The destination for statistical data is the following fixed directory on the SD card.
\Sensor name\LOGDATA
The file name is automatically created as follows.
YYYY_MM_DD-HH_mm_ss_record.csv
The date and time that make up the statistical data file name are not the date and time that the measurement
was performed, they are the date and time the statistical data file was saved from the Sensor to the Touch
Finder SD card by this command.
The file name is not case sensitive. The file name extension can be omitted.
Command (PLC to Sensor)
First word of
command
12 to 15
area
+2
1000
+3
0000
Response (Sensor to PLC)
First word of
response area
12 to 15
+2
1000
+3
0000
+4
0000
+5
0000
FQ2-S/CH User's Manual
for Communications Settings
Fixed
Time that the statistical data was saved to the Touch Finder SD card
Date that the statistical data was saved to the Touch Finder SD card
Bits
8 to 11
4 to 7
0000
0000
0000
0111
Bits
8 to 11
4 to 7
0000
0010
0000
0111
0000
0000
0000
0000
Description
0 to 3
0000
Command code
0000
Description
0 to 3
0000
Command code
The command code for which the
0000
response applies is stored.
0000
Response code
Command execution result
0000
0: OK, FFFFFFFF: NG
279
Command Control

Advertisement

Table of Contents
loading

Table of Contents