Omron FQ2-S/CH Series User Manual page 101

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

3
Set the following items on the display to set expres-
sions.
Item
Expression
Register the expression to use to output multiple data.
Examples:
Const.
Used to insert numbers and symbols into the expression.
Data
Used to select the inspection items for which to output data and insert the parameters to output
into the expression.
Example: Selecting Parameters for the Search Item at Inspection Item 0
Math.
Either of the following two functions can be inserted.
• LPR function (order of the measurement data)
The measurement data is output in order.
Format: LPR(start_number,number_of_data,data_1, data_2,...data_5)
You can omit data 2 to data 5.
• LPC function (order of the detection points)
Data is output for each detected measurement point.
Format: LPC(start_number,number_of_data,data_1, data_2,...data_5)
You can omit data 2 to data 5.
To register something to data 1 and higher, repeat this process.
The settings will be enabled after you restart the Sensor.
 Expression Setting Example
This example registers an expression to output the following inspection results for data 0.
Inspection item: 0 Search
Parameters to output: Position X, Position Y, Reference SX, and Reference SY
Multi-point output setting: Multi-point output Check Box selected, Count = 4
LPR(0,I0.C
,
I0.X,I0.Y,I0.SX,I0.SY)
Function
Number_of_data
data_A, data_B...data_d
(Detection count)
Start_number
FQ2-S/CH User's Manual
for Communications Settings
LPR (0, 3, I0.X, I0.Y)
LPC (0, I0.C, I0.X, I0.Y)
Inspection item: I0. Search
Judgement result: Judgement JG, Correlation: Corre. CR
Controlling Operation and Outputting Data with EtherNet/IP Communications
Description
99

Advertisement

Table of Contents
loading

Table of Contents