FINS Command Details
 Executing Measurements
This command executes one measurement.
If Ethernet output is not set, only the measurement is performed.
If Ethernet output is set, the measurement is performed and the result is returned as response data.
Command Format
MRC (1 byte)
SRC (1 byte)
28
0F
Response Format
MRC (1 byte)
SRC (1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Measurement result
392
Command Control
Sensor command code (4 bytes)
00101010
MRES (1 byte)
SRES
(1 byte)
End code
Command execution ended normally.
Command execution ended in an error.
• Returns the measurement result as the response when data output is set. The measurement result is
not output when data output is not set.
Setting the Data to Output Automatically after Measurements: p. 175
• Each data item requires 4 bytes.
Up to 1,024 bytes of data can be received.
Sensor command code
(4 bytes)
00101010
Meaning
for Communications Settings
Measurement result
(1,024 bytes)
Measurement result