You can specify whether to reflect the judgement result of a parallel judgement output in the overall judgement.
(The default is to reflect them.)
[In/Out] − [I/O setting] − [Output data set] − [Par. Jdg Output] − [Details] Tab Page − [Output
parameter] − [Reflect]
Stopping Data Output
You can also prevent the judgement results that are set from actually being output. (The default setting is
[Yes].)
[In/Out] − [I/O setting] − [Output data set] − [Par. Jdg Output] − [Details] Tab Page − [Output
parameter] − [Data output]
Parallel Data Output
You can output the following data as 16-bit data by setting them as the output data (data 0 to data 31):
measurement data from inspection items that can be output and the calculation results from the expression
settings.
Setting the Data to Output
You can individually assign the parameters of the inspection items to output data (data 0 to data 31).
The following procedure shows how to assign the measured position X of [0. Search] to data 0 for a parallel
output.
[In/Out] − [I/O setting] − [Output data set] − [Par. Jdg Output] − [Basic] Tab Page
1
Press [Data settings].
2
Press [Data 0].
3
Press [I0. Search].
4
Press [Position X X].
5
If the inspection item allows multi-point output,
press the number ([0] to [31]) of the inspection result
for which to output the data from the list of inspec-
tion results.
To register something to data 1 or higher, repeat this pro-
cess.
Setting the Output Form
[In/Out] − [I/O setting] − [Output data set] − [Par. Jdg Output] − [Basic] Tab Page
1
Press [Output format].
2
Press [Output form].
3
Set [Data form] to [Binary] or [BCD].
Stopping Data Output
You can also prevent the output data that is set from actually being output. (The default setting is [Yes].)
FQ2-S/CH User's Manual
for Communications Settings
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
63