Save Latest Input Image Data
Saves the latest input image to the SD card inserted in the Touch Finder as ifz data.
The destination for image data is the following fixed directory on the SD card.
\Sensor name\CAPTURE
The file name is not case sensitive. The file name extension can be omitted.
Command (PLC to Sensor)
First word of
command area
12 to 15
+2
0100
+3
0000
+4
0000
:
:
+35
0000
*1
When using the EtherNet/IP or PROFINET communication protocol, the file name is automatically created as follows.
YYYY_MM_DD-HH_mm_ss.ifz
The date and time are not recorded in the image data.
Therefore, the date and time that make up the file name are not the date and time that the measurement was performed, they are the date
and time the image data file was saved from the Sensor to the Touch Finder SD card by this command.
Response (Sensor to PLC)
First word of
response area
12 to 15
+2
0100
+3
0000
+4
0000
+5
0000
FQ2-S/CH User's Manual
for Communications Settings
Bits
8 to 11
4 to 7
0000
0010
0000
0111
0000
0000
:
:
0000
0000
Time that the image data was saved to the Touch Finder SD card
Date that the image data was saved to the Touch Finder SD card
Bits
8 to 11
4 to 7
0000
0010
0000
0111
0000
0000
0000
0000
Description
0 to 3
0000
Command code
0000
*1
0000
File name
(only when using the
PLC link communication protocol)
:
File name to save
64 characters max.
0000
The file name extension (.ifz) can
be omitted.
Refer to Specifying Char-
acter Strings: p. 206
Description
0 to 3
0000
Command code
The command code for which the
0000
response applies is stored.
0000
Response code
Command execution result
0000
0: OK, FFFFFFFF: NG
277