CGRLOAD
This command loads all calibration data that is stored on the SD card inserted in the Touch Finder.
The source for all calibration data is the following fixed directory on the SD card.
\Sensor name\CGP
<Command Format>
C G R L O A D
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
All calibration data file
name
Important
Do not turn off power to the Sensor until there is a response.
354
Command Control
C
R
All calibration data file name
Space (0x20)
Specifies the all calibration data file name to be loaded. (64 characters max.)
The file name extension (.cgp) can be omitted.
Only files with the extension "CGP" can be loaded.
FQ2-S/CH User's Manual
for Communications Settings