<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
All calibration data file name
Important
• If the specified file name already exists, this existing file will be overwritten.
• Do not turn off power to the Sensor until there is a response.
DICSAVE
Saves model dictionary data as a file to the SD card inserted in the Touch Finder.
The destination for model dictionary data is the following fixed directory on the SD card.
\Sensor name\DIC
<Command Format>
D I C S A V E
Space (0x20)
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Scene number
Model dictionary data file name
Important
• If the specified file name already exists, this existing file will be overwritten.
• Do not turn off power to the Sensor until there is a response.
364
Command Control
Specifies the all calibration data file name to be saved. (64 characters max.)
The file name extension (.cgp) can be omitted.
C
R
Model dictionary data file name
Space (0x20)
Scene number (2 digits max.)
Specifies the scene number (0 to 31) to be saved.
Specifies the file name when saving.
The file name extension (.dic) can be omitted.