MRC+SRC com-
Type of command
mand code
Save setting data com-
mands
FQ2-S/CH User's Manual
for Communications Settings
Command codes (hex)
Sensor command
code
280F
00704010
280F
00704020
280F
00705000
280F
0070A000
280F
0070B000
280F
0070C000
280F
0070D000
280F
00707000
280F
00708000
Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
Function
Saves all image data saved in the Sensor's
memory by the logging function to the SD card
inserted in the Touch Finder as ifz data.
Saves the latest input image to the SD card
inserted in the Touch Finder as ifz data.
Saves all setting data (all scene data, system
data, calibration group data) for the Sensor to
the SD card inserted in the Touch Finder as a
backup file.
Saves the calibration data with the specified
calibration number as a file to the SD card
inserted in the Touch Finder.
Saves all calibration data as a file to the SD
card inserted in the Touch Finder.
Saves the specified number of model dictionary
data as a file to the SD card inserted in the
Touch Finder.
Saves all model dictionary data as a file to the
SD card inserted in the Touch Finder.
Saves measurement data saved in the Sen-
sor's memory by the logging function to the SD
card inserted in the Touch Finder as csv data.
Saves statistical data saved in the Sensor's
memory by the logging function to the SD card
inserted in the Touch Finder as csv data.
Reference
p.443
p.449
p.444
p.445
p.446
p.447
p.448
p.450
p.451