Batch Set Terminal Status
Batch sets the ON/OFF status for the all parallel I/O output terminals other than the D terminals (D0 to D15).
Important
• Before executing this command, change the FQ2 execution mode to stop mode with the Set Execution Mode com-
mand.
• If the FQ2 is not in stop mode, some parallel terminals cannot be turned ON or OFF with this command.
Set Execution Mode: p.257
Command (PLC to Sensor)
First word of com-
mand area
12 to 15
+2
1000
+3
0000
+4
0000
+5
0000
*
These terminals status can only be set when the FQ2 execution mode is stop mode.
Response (Sensor to PLC)
First word of
response area
12 to 15
+2
1000
+3
0000
+4
0000
+5
0000
FQ2-S/CH User's Manual
for Communications Settings
Bits
8 to 11
4 to 7
0 to 3
0000
0010
0000
0000
0011
0000
0000
0000
0000
0000
0000
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0010
0000
0000
0011
0000
0000
0000
0000
0000
0000
0000
Description
Command code
Terminal status (ON: 1, OFF: 0)
• Sensor's standard parallel communications
BIT1: ERROR
BIT2: BUSY
BIT3: OR
• Parallel Interface Sensor Data Unit
BIT0: RUN
BIT1: ERROR
BIT2: BUSY
*
BIT3: OR
*
BIT5: GATE
*
BIT9: STGOUT
*
BIT11: SHTOUT
*
BIT13: ACK
• RS-232C Interface Sensor Data Unit
BIT0: RUN
BIT1: ERROR
BIT2: BUSY
*
BIT3: OR
*
BIT9: STGOUT
*
BIT11: SHTOUT
*
BIT13: ACK
Description
Command code
The command code for which the response
applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG
255