Output Order of Measurement Data and Output Characters (Only Supported on the FQ2-S4/CH Series)
When measurement data the data (output data settings 0 to 31) and characters are output together, the
characters are output after the data such as inspection item parameters and calculation results are output.
Example:
・ Inspection item 0: Bar code
As the read result is
ABC
"
・ Inspection item 1: OCR
As the read result is 2 lines.
The first line is
012
.
"
"
The second line is
345
"
"
・ [Data output] - [Data 0]: 3 (Number of characters for Bar code.)
・ [Data output] - [Data 1]: 6 (Number of characters for OCR.)
EtherNet/IP, PLC Link, PROFINET
Increment from first
address in output area
Upper byte Lower byte
+0
+1
+2
+3
+4
+5
+6
+7
+8
+9
No-protocol (TCP)
3 (Field delimiter) 6 (Record delimiter) ABC (Field delimiter) 012(Line delimiter) 345(Record delimiter) CR
CR is Delimiter, CR is not output by No-protocol (UDP) Communications.
3 (Field delimiter) 6 (Record delimiter) ABC (Field delimiter) 012 (Line delimiter)
345 (Record delimiter) CR
*1 When No-protocol communication is selected, the delimiter is not output.
FQ2-S/CH User's Manual
for Communications Settings
.
"
.
Output data
Data 0 (4 bytes)
Inspection item 0: Number of characters for Bar code.
Data 1 (4 bytes)
Inspection item 1: Number of characters for OCR.
'B'
'A'
Inspection item 0: Characters "ABC" for Bar code.
'00' is in-sorted for the character length is 4 of integral multiplica-
00
'C'
tion.
'1'
'0'
Inspection item 1: The first line is "012".
Inspection item 2: The second line is "345".
'3'
'2'
Characters are output continuously without spaces between the
lines.
'5'
'4'
'00'
'00'
00 are inserted to make the character length to the integer multi-
ple of 4.
*1
Delimiter
Assigned output data
Control Methods Using an External Device
25