Timing Chart For Profinet Communications - Omron FQ2-S/CH Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Timing Chart for PROFINET Communications

 Performing Measurements with the TRIG Signal
Command
Execute Measure-
ment (TRIG) signal
Area
Command Execution
Active (BUSY) signal
Trigger Input Ready
Response
(READY) signal
Area
Overall judgement
(OR)
(1) Measurement starts when the TRIG signal turns ON while the BUSY signal is OFF.
(2) The BUSY signal turns ON when measurement begins.
(3) The TRIG signal turns OFF when the BUSY signal turns ON.
(4) The OR of the measurement results is output when measurements are completed.
(5) The BUSY signal turns OFF when the BUSY output condition is met.
FQ2-S/CH User's Manual
for Communications Settings
ON
OFF
ON
OFF
ON
OFF
ON
OFF
(1)
(2)(3)
Outputting Data and Controlling Operation through PROFINET
(4)
(5)
167

Advertisement

Table of Contents
loading

Table of Contents