 Timing Chart
Operation When [Number of Delay] Is Set to 2
RUN signal
TRIG signal
BUSY signal
OR signal
D0 to D15 signals
GATE signal
1
Repeatedly turn ON the TRIG signal while the BUSY signal is OFF.
2
The OR signal is output when the TRIG signal is turned ON.
3
When the TRIG signal turns ON for the third time, the measurement result (D0 to D15) for the first
time that the TRIG signal turned ON is output and the GATE signal is also output at this time.
4
When the TRIG signal turns ON for the fourth time, the measurement result (D0 to D15) for the
second time that the TRIG signal turned ON is output and the GATE signal is also output at this
time.
5
Each time the TRIG signal turns ON after that, the measurement result (D0 to D15) from when the
TRIG signal turned ON two times previously is output.
72
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
Run Mode entered.
ON
OFF
ON for 1 ms min.
ON
(1)
(2)
OFF
ON while measurements are being processed
ON
OFF
Overall judgement
result for (1)
(Result not
output.)
ON
GATE ON delay
OFF
(3)
(4)
(depends on BUSY output conditions)
Overall judgement
Overall judgement
result for (2)
result for (3)
The results for (1) is output when the TRIG signal
turns ON the third time.
Result for (1)
Result for (2)
Output time
Setup Mode entered.
(5)
Overall judgement
Overall judgement
result for (4)
result for (5)
Result for (3)
Result for (4)
FQ2-S/CH User's Manual