Acquire Terminal Offset Data
This command acquires the terminal offset data that is added to the IN0 to IN4 command parameters when
executing parallel commands
If no value has been set with the Set Terminal Offset command, "00000" is returned as the terminal offset value
and "0000" (ended normally) is returned for the end code.
Set Terminal Offset Data: 280F 00504060 p. 430
Command Format
MRC
SRC
Sensor command code (4
(1 byte)
(1 byte)
bytes)
28
0F
00404060
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Parameter Descriptions
Terminal offset value
Returns the value added to the IN0 to IN4 command parameters when executing parallel commands.
FQ2-S/CH User's Manual
for Communications Settings
SRES
Sensor command code (4 bytes) Terminal offset
(1 byte)
00404060
Description
value (4 bytes)
Terminal offset
value