Set Terminal Offset Data
This command sets the value of the terminal offset data that is added to the IN0 to IN4 command parameters
when executing parallel commands.
When using parallel command scene changing, you can change the scenes to change to by changing the Set
Terminal Offset Data value.
Command (PLC to Sensor)
First word of com-
mand area
12 to 15
+2
0100
+3
0000
+4
0000
+5
0000
Response (Sensor to PLC)
First word of
response area
12 to 15
+2
0100
+3
0000
+4
0000
+5
0000
FQ2-S/CH User's Manual
for Communications Settings
Bits
8 to 11
4 to 7
0 to 3
0000
0110
0000
0000
0101
0000
0000
0000
0000
0000
0000
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0110
0000
0000
0101
0000
0000
0000
0000
0000
0000
0000
Description
Command code
Terminal offset value
Value added to the IN0 to IN4 command
parameters when executing parallel com-
mands
Description
Command code
The command code for which the response
applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG