Omron FQ2-S/CH Series User Manual page 236

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

System
Type
data num-
ber
103
Logging
control
104
Logging
control
106
Parallel
control
107
Parallel
control
108
Parallel
control
109
Parallel
control
110
Parallel
control
111
Parallel
control
112
Parallel
control
113
Parallel
control
234
Command Control
Item
Data
Range
size
Measurement
4
0: None
data
1: All
2: NG only
Statistical data
4
0: None
1: Yes
OR output
4
0: OK: ON
1: NG: ON
Output delay
4
0 to 1,000
Judgment out-
4
0: Level output
put mode
1: One-shot output
One-shot out-
4
1 to 1,000
put time
OUT0 polarity
4
0: Positive
1: Negative
OUT1 polarity
4
0: Positive
1: Negative
OUT2 polarity
4
0: Positive
1: Negative
OUT0 signal
4
0: Control signal
assignment
1 to 32: OR0 to 31
1001 to 1032: Expression 1 to 32
2001: OR (overall judgement)
2002: BUSY
2003: ERROR
2004: READY
2005: RUN
2006: STG
Description
Specifies the logging con-
dition for measurement
data for each inspection
item.
Specifies whether or not to
record statistical data (such
as the number of measure-
ments, number of NG judg-
ments).
Specifies the polarity when
the OUT0 output signal is
ON.
Specifies the ON delay
time (ms) from when the
measurement processing
completes until output
when using one-shot out-
put.
Specifies whether output is
one-shot output or level
output.
Specifies the ON output
time (ms) when using one-
shot output.
Specifies the polarity for
the OUT0 output signal
(default assignment:
BUSY).
Specifies the polarity for
the OUT1 output signal
(default assignment: OR).
Specifies the polarity for
the OUT2 output signal
(default assignment:
ERROR).
Specifies whether to use
the signal as a control sig-
nal or to use the signal as a
judgment output (OR indi-
vidual output signal) for
inspection items.
FQ2-S/CH User's Manual
for Communications Settings

Advertisement

Table of Contents
loading

Table of Contents