Acquire Statistical Data
Acquires the statistical data (such as the number of measurements, number of NG overall judgments, and
other information, since the power supply was turned ON) possessed by the Sensor.
The following types of statistical data are available. Specify the data to be read from these types with this
command.
• Number of measurements since the power supply was turned ON
• Number of OK overall judgments
• NG rate
• Number of NG judgments since the power supply was turned ON
• OK rate
Command Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Type of statistical data to
be acquired
Acquired value
424
Command Control
Sensor command code (4
bytes)
00406010
MRES
SRES
(1 byte)
(1 byte)
End code
Command execution ended normally.
Command execution ended in an error.
Specifies the type of statistical data to be acquired.
1: Number of measurements
2: Number of NG judgments
3: NG rate
4: Number of OK judgments
5: OK rate
Returns the value of the acquired statistical data.
Type of statistical data to be
acquired (4 bytes)
1 digit max.
Sensor command code (4 bytes) Acquired value
00406010
Description
(4 bytes)
Acquired value
(1,000 times the
actual value)
FQ2-S/CH User's Manual