<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
TIMER or TMR
This command executes the specified command after the specified waiting time elapses.
<Command Format>
T I M E R
Space (0x20)
or
T M R
Space
(0x20)
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Waiting time (msec)
Specifies the waiting time for the command that will be executed with this command. (100 to
99,999)
Command string
Specifies the string for the command that will be executed with this command.
Only one type of command can be specified for execution with this command.
This timer command cannot be specified.
FQ2-S/CH User's Manual
for Communications Settings
C
R
Command string
Space (0x20)
Waiting time (msec)
C
R
Command string
Space (0x20)
Waiting time (msec)