Acquire Communication Input Status
This command acquires the input status (allowed/prohibited) for the communications protocol set with the Set
Communication Input Status command.
Command (PLC to Sensor)
First word of com-
mand area
+2
+3
+4
+5
Response (Sensor to PLC)
First word of
response area
+2
+3
+4
+5
+6
+7
240
Command Control
Bits
12 to 15
8 to 11
4 to 7
0111
0000
0001
0000
0000
0010
0000
0000
0000
0000
0000
0000
Bits
12 to 15
8 to 11
4 to 7
0111
0000
0001
0000
0000
0010
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Description
0 to 3
0000
Command code
0000
0000
Communications protocol type to be acquired
0: No protocol (TCP, UDP, FINS)
0000
1: No protocol (RS-232C)
2: Parallel I/O
3: Fieldbus
5: PLC link
Description
0 to 3
0000
Command code
The command code for which the response
0000
applies is stored.
0000
Response code
Command execution result
0000
0: OK, FFFFFFFF: NG
0000
Acquired communications protocol status
0: Input prohibited status
0000
1: Input allowed status
*