Omron FQ2-S/CH Series User Manual page 113

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Important
After you execute the Reset command (0010F010 hex) for the Sensor, turn OFF the EXE signal before the Sensor
restarts. If you leave the EXE signal ON, the Sensor will restart repeatedly.
 Commands to Get Status
Command code in
command area (hex)
+2
+3
1000
0020
Get Scene Number
 Commands to Set Status
Command code in
command area (hex)
+2
+3
1000
0030
Select Scene
 Commands to Read Data
Command code in
command area (hex)
+2
+3
1010
0040
Get Image Adjustment Item
Data
1020
0040
Get Inspection Item Data
1040
0040
Acquire Camera Parameter
2000
0040
Acquire Date and Time Infor-
mation
3000
0040
Get Software Version Informa-
tion
4010
0040
Acquire System Data
4060
0040
Acquire Terminal Offset Data
6010
0040
Acquire Statistical Data
FQ2-S/CH User's Manual
for Communications Settings
Command name
Acquires the scene number currently being
used.
Command name
Changes the scene number to be used.
Command name
Acquires parameters and measurement val-
ues for a position compensation item or filter
item.
Acquires parameters and measurement val-
ues for the specified inspection item.
Acquires the value of the specified camera
parameter.
Acquires the current date and time informa-
tion.
Acquires the Sensor's software version.
Acquires the value set for the specified sys-
tem data.
Acquires the terminal offset data that is
added to the IN0 to IN4 command parame-
ters when executing parallel commands.
Acquires the statistical data (such as the
number of measurements, number of NG
overall judgments, and other information,
since the power supply was turned ON) held
by the Sensor.
Controlling Operation and Outputting Data with EtherNet/IP Communications
Function
Function
Function
Reference
p.226
Reference
p.226
Reference
p.227
p.228
p.229
p.246
p.232
p.233
p.237
p.238
111

Advertisement

Table of Contents
loading