List Of Fins Commands - Omron FQ2-S/CH Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Initial Settings for FINS/TCP No-protocol Communications
You must set the communications method of the destination external device to perform no-protocol
communications.
[Sensor settings] − [Data output] − [No-protocol data]
1
Press [No protocol (FINS/TCP)].
2
Set [Connection mode] to either [TCP server] or [TCP
client]. When you are finished, press [Back].
3
If you set [Connection mode] to [TCP client], set the
following parameters.
Initial settings for FINS communications
Items to set and their default values depend on the communication protocol used and connection mode set.
Communication protocol
used and connection mode
set
No protocol (FINS/TCP)
TCP server
No protocol (FINS/TCP)
TCP client

List of FINS Commands

Command List
The following table lists the FINS commands.
Commands that can be used in FINS Ethernet communications are listed below.
FQ2-S/CH User's Manual
for Communications Settings
Item
Sets the input port number to wait for a connec-
tion request from the connected external device
(or client) such as a PLC.
Input port
In this connection mode, an FQ2 Sensor serves
No.
as a TCP server and monitors this port number
to be ready for the connection request from the
client.
Output IP
Sets the IP address of the connected external
address
device (PLC, etc.).
Sets the port number to be used for exchanging
data with the connected external device (or cli-
ent) such as a PLC.
Port No.
Set the same port number as the port number
set for the connected external device.
Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
Description
Setting range
0 to 65,535
Default: 9,876
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 1 to 254
Default: 10.5.5.111
0 to 65,535
Default: 9,600
195