Set Terminal Offset Data
This command sets the value of the terminal offset data that is added to the IN0 to IN4 command parameters
when executing parallel commands.
When using parallel command scene changing, you can change the scenes to change to by changing the Set
Terminal Offset Data value.
Note
When using the Sensor in Expanded Mode while using the standard parallel interface of the Sensor, the range of
scene numbers that can be changed to with scene changing is limited to 0 through 15. By offsetting the command
parameter with this command, the scene can be changed to scene number 0 through 31.
Command Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Terminal offset value
430
Command Control
Sensor command code (4
bytes)
00504060
MRES
SRES
(1 byte)
(1 byte)
End code
Command execution ended normally.
Command execution ended in an error.
Specifies the value to be added to the IN0 to IN4 command parameters when executing parallel com-
mands.
Terminal offset value (4 bytes)
2 digits max.
Sensor command code (4 bytes)
00504060
Description