Load Scene Data
Loads scene data that is stored on the SD card inserted in the Touch Finder.
The source for scene data is the following fixed directory on the SD card.
\Sensor name\SCN
The file name is not case sensitive. The file name extension can be omitted.
Note
All of output signals are turned OFF after executing commands.
When the command is executed at the Sensor Data Unit is connected, output signals except RUN signal are turned
OFF.
Command (PLC to Sensor)
First word of com-
mand area
12 to 15
+2
0001
+3
0000
+4
0000
+5
0000
+6
0000
+7
0000
+8
0000
:
:
+37
0000
*1
Loads the files named Scene_***.scn saved on the SD card. (***: Specified file number)
Response (Sensor to PLC)
First word of
response area
12 to 15
+2
0001
+3
0000
+4
0000
+5
0000
FQ2-S/CH User's Manual
for Communications Settings
Bits
8 to 11
4 to 7
0 to 3
0000
0000
0000
0000
0110
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
:
:
:
0000
0000
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0000
0000
0000
0110
0000
0000
0000
0000
0000
0000
0000
Contents
Command code
The number of the scene to be loaded.
• EtherNet/IP,
• PLC link
PROFINET
File name to load
64 characters max.
File number to load
(0 to 999)*1
---
Specifying Character
Strings: p. 206
Contents
Command code
Response target command codes
Response code
Command execution result
0: OK, FFFFFFFF: NG
Refer to