Omron FQ2-S/CH Series User Manual page 218

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

End Continuous Measurements
This command ends continuous measurements.
Command (PLC to Sensor)
First word of com-
mand area
+2
+3
Response (Sensor to PLC)
First word of
response area
+2
+3
+4
+5
Clear Measurement Values
This command clears the measurement values.
Command (PLC to Sensor)
First word of com-
mand area
+2
+3
Response (Sensor to PLC)
First word of
response area
+2
+3
+4
+5
216
Command Control
Bits
12 to 15
8 to 11
4 to 7
0001
0000
0011
0000
0000
0001
Bits
12 to 15
8 to 11
4 to 7
0001
0000
0011
0000
0000
0001
0000
0000
0000
0000
0000
0000
Bits
12 to 15
8 to 11
4 to 7
0010
0000
0001
0000
0000
0001
Bits
12 to 15
8 to 11
4 to 7
0010
0000
0001
0000
0000
0001
0000
0000
0000
0000
0000
0000
Contents
0 to 3
0000
Command code
0000
Contents
0 to 3
0000
Command code
The command code for which the response
0000
applies is stored.
0000
Response code
Command execution result
0000
0: OK, FFFFFFFF: NG
Contents
0 to 3
0000
Command code
0000
Contents
0 to 3
0000
Command code
The command code for which the response
0000
applies is stored.
0000
Response code
Command execution result
0000
0: OK, FFFFFFFF: NG
FQ2-S/CH User's Manual
for Communications Settings

Advertisement

Table of Contents
loading

Table of Contents