Omron FQ2-S/CH Series User Manual page 47

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Adjusting the End Timing of the BUSY Signal
The end timing of the BUSY signal can be changed.
[In/Out] − [I/O setting] − [I/O setting] − [Output] Tab Page − [BUSY output]
Item
Measurement (default)
Data logging
BUSY output
Image logging
Result display
Important
Do not disconnect the Ethernet cable between the Sensor and the Touch Finder if the Sensor and Touch Finder are
connected through an Ethernet switch and the BUSY output condition is set to [Data logging], [Image logging], or
[Result display].
The Sensor will wait for the Touch Finder to answer, and the results and measurement time will be affected.
To disconnect the Sensor and Touch Finder during measurements in the above situation, clear the selection of the
Sensor from the list of Sensors on the Touch Finder before you disconnect the cable.
Changing the Assignment of Output Signals
Output signals (OUT0 to OUT2) are able to change these assignments.
Settings
[In/Out] − [I/O setting] − [I/O setting] − [Output] − [OUT0 Polarity], [OUT1 Polarity] or [OUT2
Polarity]
For the signal's type that are able to assign, refer to the following page.
Getting Individual Judgment and Expression Judgments: p. 41
Changing the Polarity of the Output Signals
You can change the polarity of the output signals that are assigned to OUT0 to OUT3 (regardless of what
signal is assigned to the output).
Settings
[In/Out] − [I/O setting] − [I/O setting] − [Output] − [OUT0 Polarity], [OUT1 Polarity] or [OUT2
Polarity]
Item
Positive (default)
OUT0 Polarity,
OUT1 Polarity, or
Negative
OUT2 Polarity
FQ2-S/CH User's Manual
for Communications Settings
The BUSY signal turns OFF when the measurement is completed.
The BUSY signal turns OFF when data logging is completed.
The BUSY signal turns OFF when image logging is completed.
The BUSY signal turns OFF when the result display is completed.
The output signal that is assigned to OUT0 to OUT3 is turned ON when the Sen-
sor is executing a process.
The output signal that is assigned to OUT0 to OUT3 is turned ON when the Sen-
sor can receive the trigger.
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
Description
Description
45

Advertisement

Table of Contents
loading