Omron FQ2-S/CH Series User Manual page 81

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Input Signals
Signal
IN0
Turn ON.
IN1 to IN5
Turn OFF.
IN6
Turn ON.
IN7
This signal is the trigger for clearing an error.
Set the IN0 to IN6 signals, wait for at least 5 ms, and then turn ON the IN7 signal.
Re-registering the Model and Reference Color
This command is input from an external devices, such as a PLC, to re-register the models and reference colors
for registered inspection items based on the image that was just input.
Search, Shape Search III, Shape Search II, Sensitive Search,
Color Data
Edge Position, Edge Width, Edge Pitch, Area, and Labeling
Parameters
Execution
IN7
IN6
IN5
1
Timing Chart
RUN signal
IN0 to IN6 signals
IN7 signal
Allow 5 ms min.
and then turn ON IN7.
BUSY signal
ACK signal
FQ2-S/CH User's Manual
for Communications Settings
Inspection items
Command
IN4
IN3
1001000
Run Mode entered.
ON
OFF
0
1001000
ON for 1 ms min.
ON
OFF
ON
Command execution
OFF
ON
OFF
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
Function
Models
Reference color (hue, saturation, and brightness)
None
IN2
IN1
IN0
ACK output time
Re-registered data
Input example
11001000