Omron FQ2-S/CH Series User Manual page 16

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Commu-
Communi-
nications
cations
method
protocol
No-protocol
(TCP)
No-protocol
(UDP)
Frame
transmis-
No-protocol
*1
sion
(RS-232C)
No-protocol
(FINS/TCP)
*1:
When connected to a CJ-series PLC, specify the areas in the I/O memory.
*2:
This connection is via the RS-232C Interface Sensor Data Unit. Only supported on the FQ2-S3/S4/CH series.
Connection Compatibility
Type of connection to
FQ2-S/CH
EtherNet/IP
PLC Link on Ethernet
PROFINET
TCP no-protocol communi-
cations on Ethernet,
UDP no-protocol communi-
cations on Ethernet
FINS/TCP no-protocol com-
munications on Ethernet
*1
RS-232C
Parallel
Sensor's stan-
communi-
dard parallel
cations
communica-
tions
Parallel Inter-
*2
face
*1:
This applies when an RS-232C Interface Sensor Data Unit is connected.
*2:
This applies when a Parallel Interface Sensor Data Unit is connected.
14
Communicating with an External Device
Overview
Command frames are sent to the Sensor and response
frames are received from the Sensor without the use of
any specific protocol.
Data can be exchanged between the PLC, computer, or
other external device and the Sensor by sending and
receiving ASCII or binary format data.
Control and Output in No-Protocol (TCP) / No-Proto-
col (UDP): p.173
Commands or inspect item parameters are transfered or
received between Sensor Data Unit and or RS-232C
cables in No-protocol communication.
Introduction to RS-232C Connections: p.202
This is a command system (FINS) for message services
that can be used in common on OMRON networks. Data
can be exchanged between an OMRON PLC and the
Sensor by a command/response method.
Controlling Operation and Outputting Data with
FINS/TCP No-protocol Commands p.193
EtherNet/IP PLC Link
PROFINET TCP no-protocol
on Ethernet
---
No
No
No
---
No
No
No
---
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Communications cable type
Parallel
I/O
---
---
---
Yes: Supported, No: Not supported
Other connection
FINS/TCP
RS-232C
communications on
no-proto-
Ethernet,
col commu-
UDP no-protocol
nications
communications
on Ethernet
on Ethernet
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
---
No
No
No
---
No
No
No
---
Yes
Yes
Yes
Yes
Yes
No
Ethernet RS-232C
OK
---
*2
---
OK
OK
---
*1
Parallel communications
Sensor's
Parallel
*2
standard
Interface
parallel com-
munications
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
---
No
No
---
FQ2-S/CH User's Manual
for Communications Settings

Advertisement

Table of Contents
loading

Table of Contents