Set Image Adjustment Data
This command sets parameters or measurement ranges from a position compensation item or filter item.
Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Position compensation
item number
External reference num-
ber
Set value
426
Command Control
Sensor command code (4
bytes)
00501010
MRES
SRES
(1 byte)
(1 byte)
End code
Command execution ended normally.
Command execution ended in an error.
Specifies the number of the position compensation item or filter item to set. (0 to 31)
Specifies the external reference number.
Section 9-2 External Reference Parameters
in Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
Specifies the set value.
Section 9-2 External Reference Parameters
in Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
Position compensation item/filter
item number (4 bytes)
Position compensation item/filter
item number 0 to 7 (1 digit max.)
Sensor command code (4 bytes)
00501010
Description
External reference
Set value (4 bytes)
number (4 bytes)
External reference
Setting value
number
(1,000 times the
actual value)
FQ2-S/CH User's Manual