ITEMDATA or ID
Acquire Inspection Item Data
This command acquires the parameters of the specified inspection item.
<Command Format>
Command
I
T
E
M
D
A
or
I
D
Inspection item
Command
number
(2 digits max.)
Space
Space
(0x20)
(0x20)
<Response Format>
When the Command Is Processed Normally
Acquired
CR
value
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Inspection item number
External reference data
number
Acquired value
FQ2-S/CH User's Manual
for Communications Settings
Inspection item number
(2 digits max.)
T
A
Space
(0x20)
CR
External reference
data number
(4 digits max.)
Specifies the inspection item number. (0 to 31)
Specifies the external reference data number. (0 to 9999)
Section 9-2 External Reference Parameters
in Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
Returns the data for the specified inspection item.
Section 9-2 External Reference Parameters
in Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
External reference
data number
(4 digits max.)
CR
Delimiter
Space
(0x20)
Delimiter