Load Setting Data Commands
SCNLOAD
This command loads scene data that is stored on the SD card inserted in the Touch Finder.
The source for scene data is the following fixed directory on the SD card.
\Sensor name\SCN
<Command format>
S C N L O A D
Space (0x20)
<Response format>
When Processing Is Performed Normally
When Processing Is Not Performed Normally
<Parameter Descriptions>
Scene No.
File name of scene data
Important
Do not turn off power to the Sensor until there is a response.
FQ2-S/CH User's Manual
for Communications Settings
C
R
File name of scene data
Space (0x20)
Scene No. (2 digits max.)
Specifies the scene No. to be read (0 to 31)
Specifies the scene data file name you want to load. (64 characters max.)
Only files that have an "SCN" extension can be read.