Controlling Operation from an External Device

The following Sensor functions can be controlled with command inputs from an external device without
connecting the Touch Finder.
Operation
Switching the scene
Clearing measurement
values
Clearing an error
Re-registering the model
and reference color
Teaching
Clearing the OR and D sig-
nals
Saving data in the Sensor This command saves the current settings (scene data and system data)
Retrying Inspection by
External
Signal (trigger retry)
Input Format (IN7 to IN0)
IN7 IN6 IN5 IN4 IN3 IN2 IN1 IN0
Command
Execution
Changing the Scene
This command changes the scene to shift to a different process.
Parameters
Execution
Command
IN7
IN6
IN5
1
01
FQ2-S/CH User's Manual
for Communications Settings
This command changes the scene when the line process changes.
This command clears the measurement values.
The OR signal and D signals are not cleared.
This command turns the ERROR signal OFF.
The ERROR indicator is also turned OFF.
This command re-registers the model and reference color.
This command uses the image that is currently being input to execute
teaching for all of the registered items.
This command clears the OR signal and D signals.
in the Sensor.
This command continues inspection when the trigger signal is ON.
IN4
IN3
Input the scene number as a binary value.
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
Description
IN2
IN1
IN0
Reference
p. 75
p. 76
p. 77
p. 79
p. 80
p. 81
p. 82
p. 84
Input example
10100001
(Changes to scene 1.)
75