Omron FQ2-S/CH Series User Manual page 350

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

SYSDATA or SD
Set System Data
Sets the value to the specified system data.
System data numbers and details: p. 233
Note
All output signals are turned OFF after command is executed.
All output signals except RUN signal are turned OFF when Sensor Data Unit is connected.
<Command Format>
Command
S
Y
S
D
or
S
D
Command
System data
number
(3 digits max.)
Space
(0x20)
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
System data number*
Setting value
348
Command Control
System data number
(3 digits max.)
A
T
A
Space
(0x20)
Setting value
(5 digits max.)
Space
(0x20)
Specifies the number that corresponds to the system data to be set.
Specifies the setting value to be set to the system data.
Setting value
(5 digits max.)
Space
(0x20)
CR
Delimiter
CR
Delimiter
FQ2-S/CH User's Manual