Set Terminal Status
This command sets the output signal ON/OFF status for the specified parallel I/O terminal.
Note
When turning the parallel terminals ON or OFF with this command, there are terminals that cannot be controlled if
the FQ2 execution mode is not set to stop mode.
In this case, first change the FQ2 execution mode to stop mode with the Set Execution Mode command, and then
execute this command.
Set Execution Mode: p.417
Command Format
MRC
SRC
Sensor command code (4
(1 byte)
(1 byte)
bytes)
28
0F
00308010
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
FQ2-S/CH User's Manual
for Communications Settings
Terminal type (4 bytes)
2 digits max.
SRES
Sensor command code (4 bytes)
(1 byte)
00308010
Description
Terminal number
Terminal status
(4 bytes)
(4 bytes)
1 digit max.
1 digit max.
Command Control
413