Set Communication Output Status
This command sets the output status (allowed/prohibited) of the communications port for all the
communications protocol.
Communications protocols with the output status set to prohibited will no longer output signals after being set
as such.
Command (PLC to Sensor)
First word of com-
mand area
12 to 15
+2
0111
+3
0000
+4
0000
+5
0000
Response (Sensor to PLC)
First word of
response area
12 to 15
+2
0111
+3
0000
+4
0000
+5
0000
Set Terminal Status
This command sets the output signal ON/OFF status for the specified parallel I/O terminal.
Note
When turning the parallel terminals ON or OFF with this command, there are terminals that cannot be controlled if
the FQ2 execution mode is not set to stop mode. In this case, first change the FQ2 execution mode to stop mode
with the Set Execution Mode command, and then execute this command.
Set Execution Mode: p.257
FQ2-S/CH User's Manual
for Communications Settings
Bits
8 to 11
4 to 7
0 to 3
0000
0010
0000
0000
0011
0000
0000
0000
0000
0000
0000
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0010
0000
0000
0011
0000
0000
0000
0000
0000
0000
0000
Description
Command code
Communications protocol status to be set
0: Output prohibited status
1: Output allowed status
Description
Command code
The command code for which the response
applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG