Save All Calibration Data
Saves all calibration data as a file to the SD card inserted in the Touch Finder.
The destination for all calibration data is the following fixed directory on the SD card.
\Sensor name\CGP
Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
All calibration data file
name
Important
• If the specified file name already exists, this existing file will be overwritten.
• Do not turn off power to the Sensor until there is a response.
446
Command Control
Sensor command code (4
bytes)
0070B000
MRES
SRES
(1 byte)
(1 byte)
End code
Description
Command execution ended normally.
Command execution ended in an error.
Specifies the all calibration data file name to be saved.
The file name extension (.cgp) can be omitted.
All calibration data file name
(4 to 64 bytes)
64 characters max.
Sensor command code (4 bytes)
0070B000