MRC+SRC com-
Type of command
mand code
Commands to get status
FQ2-S/CH User's Manual
for Communications Settings
Command codes (hex)
Sensor command
code
280F
00205000
280F
00207010
280F
00207020
280F
00208010
280F
00208020
280F
00208030
280F
0020F000
280F
00401010
280F
00401020
280F
00401040
280F
00403000
280F
00404010
280F
00404060
280F
00406010
Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
Function
Acquires the Sensor's most recent error code.
Acquires the input status (allowed/prohibited)
for the communications protocol set with the
Set Communication Input Status command.
Acquires the output status (allowed/prohibited)
for the communications protocol set with the
Set Communication Output Status command.
Acquires the input signal ON/OFF status for the
specified parallel I/O terminal.
Batch acquires the ON/OFF status for the all
parallel I/O input terminals other than the IN ter-
minals.
Batch acquires the ON/OFF status for the IN
terminals.
Acquires the FQ2 execution status (execution
mode).
Acquires parameters and measurement values
for a position compensation item or filter item.
Acquires parameters and measurement values
for the specified inspection item.
Acquires the value of the specified camera
parameter.
Acquires the Sensor's software version.
Acquires the value set for the specified system
data.
Acquires the terminal offset data that is added
to the IN0 to IN4 command parameters when
executing parallel commands.
Acquires the statistical data (such as the num-
ber of measurements, number of NG overall
judgments, and other information, since the
power supply was turned ON) held by the Sen-
sor.
Reference
p.425
p.404
p.405
p.406
p.407
p.408
p.409
p.418
p.419
p.421
p.420
p.422
p.423
p.424