Omron FQ2-S/CH Series User Manual page 44

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Timing Chart
Output OR0 to OR31 signals are held until the next judgement output.
TRIG signal
BUSY signal
Example:
OR0 signal
OR1 signal
*1:
The timing for updating the OR signal is when the measurement results are finalized, regardless of the output settings of the BUSY signal
(BUSY output conditions).
Settings
[In/Out] − [I/O setting] − [I/O setting] − [Output]
1
Press [OUT0].
2
Press [OR2 (Item 2 judgement)].
OR2 output signal was assigned to OUT0.
3
Assign the others in the following manner.
OUT1: OR5
OUT2: OR14
Adjusting the Judgement Output Timing
The output timing of the OR signal or OR0 to OR31 signals can be selected from two modes depending on the
external device.
Selecting the OFF Timing
 Level output (default)
The status of the output OR signal is held until the next OR signal is output.
TRIG signal
BUSY signal
OR signal
42
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
ON
ON for 1 ms min.
OFF
ON
ON while measurements are
OFF
being processed (depends
on BUSY output conditions)
ON
ON for 1 ms min.
OFF
ON
ON while measure-
OFF
ments are being
processed (depends
on BUSY output
conditions)
ON
OFF
Overall judgement
(OR output: ON for NG)
Turned ON when individual
judgement is NG.
(OR output: ON for NG)
Turned ON when individual
judgement is NG.
(OR output: ON for NG)
Individual
*1
judgement
NG
Held until the next
judgement result is output
OK
FQ2-S/CH User's Manual
for Communications Settings

Advertisement

Table of Contents
loading