Important
It may happen that the PLC is unable to recognize BUSY signal ON because the cycle time is slow or otherwise. In
this event, have W0.00 turn OFF at a suitable time.
Saving Data in Sensor
You can save the current settings (scene data and system data) in the Sensor.
Note
• This command is only valid in Expanded Mode.
• This function can be used in Run Mode only.
Wiring
Color
Signal
Gray
IN0
Green
IN1
Red
IN2
White
IN3
Purple
IN4
Yellow
IN5
Orange
OUT1 (BUSY)
Timing Chart
IN0 to IN4
signals
ON
IN5 signal
OFF
ON
BUSY
signal
OFF
FQ2-S/CH User's Manual
for Communications Settings
State
ON
OFF
OFF
Command parameters for saving data to
the Sensor
OFF
OFF
ON
Command input for saving data to the
Sensor
--
Processing in progress (default)
Allow 5 ms min. and then
turn ON IN5.
ON for 1 ms min.
Saving data in
Saving data
Sensor completed.
in Sensor started.
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
Description
The signals shown at the left
are used.
Refer
information for signal wiring.
1Turn ON IN0 and turn OFF IN1 to IN4.
2Turn ON the IN5 signal while the BUSY
signal is OFF to save the data in the
Sensor.
to
the
following
Section 2 Installation
and Connections
in Sensor
FQ2-S/CH Series
User's Manual
(Cat. No. Z337)
57