Omron FQ2-S/CH Series User Manual page 341

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

ITEMDATA Command or ID
Set Inspection Item Data
This command sets the parameters of the specified inspection item.
<Command Format>
Command
I
T
E
M
D
A
or
I
D
Inspection item
Command
number
(2 digits max.)
Space
Space
(0x20)
(0x20)
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Inspection item number
External reference data
number
Setting value
FQ2-S/CH User's Manual
for Communications Settings
Inspection
item number
(2 digits max.)
T
A
Space
Space
(0x20)
External reference
data number
(4 digits max.)
Space
(0x20)
Specifies the inspection item number. (0 to 31)
Specifies the external reference data number. (0 to 9999)
Section 9-2 External Reference Parameters
in Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
Specifies the setting value.
Section 9-2 External Reference Parameters
in Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
External reference
data number
(4 digits max.)
Space
(0x20)
(0x20)
Setting
CR
value
Delimiter
Setting
CR
value
Delimiter
Command Control
339

Advertisement

Table of Contents
loading

Table of Contents