Registering the Measurement Reference Again
When the line process is changed or otherwise, the model and reference color can be re-registered based on
the previously loaded image. Data that can be re-registered with the re-registration command are shown
below.
Inspection item
Search, Shape Search II, Shape Search
III
Color Data
Edge Position, Edge Width, Area
Note
• This command is only valid in Expanded Mode.
• Application is possibly only from the Run Mode
• If the parameter is applicable to more than one inspection item, it will be re-registered for all inspection items.
Settings
[In/Out] − [I/O setting] − [I/O setting] − [Input] − [Input mode]
Press [Expand mode].
Wiring
Color
Signal
State
Gray
IN0
OFF
Green
IN1
OFF
Red
IN2
OFF
White
IN3
ON
Purple
IN4
OFF
Yellow
IN5
ON
Orange OUT1 (BUSY)
--
Timing Chart
IN0 to IN4 signals
ON
IN5 signal
OFF
ON
BUSY signal
OFF
FQ2-S/CH User's Manual
for Communications Settings
Model data
Reference color (hue, saturation, and brightness)
None
Description
Command parameter for registering the mea-
surement reference again
Command input for registering the measure-
ment reference again
Processing in progress (default)
Allow 5 ms min. and then turn
ON IN5.
ON for 1 ms min.
Start re-registering
End re-registering
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
Re-registered data
The signals shown at the left are
used.
Refer to the following information
for signal wiring.
Section 2 Installation and
Connections
in Sensor FQ2-S/CH Series
User's Manual
(Cat. No. Z337)
1Turn OFF IN0 to IN4 and turn ON IN3.
2Turn ON the IN5 signal while the BUSY
signal is OFF to register the model data
and reference color again from the image
that was just input.
3The BUSY signal turns ON while the
parameters are being re-registered.
49