• Data Type to Access the Command Area
Name of data type: S_EIPOutput
Type of derivative data type: Structure
Name of data type
S_EIPOutput
ControlFlag
CommandCode
CommandParam1
CommandParam2
CommandParam3
• Assignment Example for Variable Data Type That Matches the Command Area
Control
Flag
Command
Code
S_EIP
Command
Output
Param1
Command
Param2
Command
Param3
• Data Type to Access the Response and Output Areas
Name of data type: S_EIPInput
Type of derivative data type: Structure
Name of data type
S_EIPInput
StatusFlag
CommandCodeEcho
ResponseCode
ResponseData
OutputData
106
Controlling Operation and Outputting Data with EtherNet/IP Communications
Data type
STRUCT
U_EIPFlag
DWORD
UDINT
UDINT
DINT
15
14
13
12
11
+0
ERCLR
+1
+2
+3
+4
+5
+6
+7
+8
+9
Data type
STRUCT
U_EIPFlag
DWORD
UDINT
DINT
ARRAY[0..7]OF DINT
The data type that was defined above (1)
32-bit bit string data
32-bit integer data
32-bit integer data
32-bit integer data
Bits
10
9
8
7
6
5
Command code
Parameter 1
Parameter 2
Parameter 3
The data type that was defined above (1)
32-bit bit string data
32-bit integer data
32-bit integer data
Specifies an array of DINT
data from 0 to 7.
for Communications Settings
4
3
2
1
0
TRIG EXE