 Clear Statistical Data
This command clears the statistical data (such as the number of measurements, the number of NG overall
judgments, the NG rate, and other information since the power supply was turned ON) produced by the logging
function held by the Sensor.
Command Format
MRC (1 byte)
SRC (1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
 Save Data in the Sensor: 280F 00103010
This command saves the current setting data (system data, scene groups, and calibration data) in the Sensor.
Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
394
Command Control
Sensor command code (4
bytes)
00102060
MRES
SRES
(1 byte)
(1 byte)
End code
Command execution ended normally.
Command execution ended in an error.
Sensor command code (4
bytes)
00103010
MRES
SRES
(1 byte)
(1 byte)
End code
Command execution ended normally.
Command execution ended in an error.
Sensor command code (4 bytes)
00102060
Description
Sensor command code (4 bytes)
00103010
Meaning