Omron FQ2-S/CH Series User Manual page 318

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

PARAPORTCOND or PPC
Acquire Terminal Status
Acquires the input signal ON/OFF status for the specified parallel I/O terminal.
<Command Format>
P
A
R
A
Space
or
(0x20)
C
P
P
Command
Terminal type
(2 digits max.)
<Response Format>
When the Command Is Processed Normally
Acquired
CR
value
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
316