Set Communication Input Status
This command sets the input status (allowed/prohibited) of the communications port for the specified
communications protocol.
Communications protocols with the input status set to prohibited will no longer receive communications after
being set as such.
However, for inputs related to hardware (parallel TRIG signal and DSA signal), this setting is not applicable.
Command Format
MRC
SRC
Sensor command code (4
(1 byte)
(1 byte)
bytes)
28
0F
00307010
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Parameter Descriptions
Communications proto-
Specifies the type of communications protocol to be set.
col type to be set
0: No protocol (TCP, UDP, FINS)
1: No protocol (RS-232C)
2: Parallel I/O
3: Fieldbus
5: PLC link
Setting value
Sets the status of the communications protocol.
0: Input prohibited status
1: Input allowed status
FQ2-S/CH User's Manual
for Communications Settings
Communications protocol type to
be set (4 bytes)
Communications protocol type to
be set (1 digit max.)
SRES
Sensor command code (4 bytes)
(1 byte)
00307010
Description
Setting value (4 bytes)
Communications protocol status
to be set (1 digit max.)