Omron FQ2-S/CH Series User Manual page 245

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Batch Acquire Terminal Status
Batch acquires the ON/OFF status for the all parallel I/O input terminals other than the IN terminals.
Command (PLC to Sensor)
First word of com-
mand area
12 to 15
+2
1000
+3
0000
Response (Sensor to PLC)
First word of
response area
12 to 15
+2
1000
+3
0000
+4
0000
+5
0000
+6
0000
+7
0000
FQ2-S/CH User's Manual
for Communications Settings
Bits
8 to 11
4 to 7
0 to 3
0000
0010
0000
0000
0010
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0010
0000
0000
0010
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Description
Command code
Description
Command code
The command code for which the response
applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG
Terminal status (ON: 1, OFF: 0)
BIT0: TRIG
BIT1: DSA
BIT4: RESET
243
Command Control

Advertisement

Table of Contents
loading

Table of Contents