Setting the Output Format
[In/Out] − [I/O setting] − [Output data setting] − [Link data output/Fieldbus data output]
1
Press [Output format].
2
Press [Output form].
3
Set either a floating point decimal or a fixed decimal for the output form.
Item
Output form
Set the output form for numerical data.
Fixed decimal point
Outputs the data as a x1000 value.
Example: 123.456 is output as 0x0001E240
Floating decimal point
Outputs the data in floating point decimal for-
mat.
Example: −123.4567 is output as 0xc2f6e979
Outputting Character Strings (Only Supported on the FQ2-S4/CH)
You can set whether to output the character string that results from reading. Outputting the character string is
possible for the following inspection results.
• OCR
Reading and Verifying Character Strings in FQ2-S/CH Series User's Manual (Cat. No. Z337)
• Bar code
Reading Bar Codes in FQ2-S/CH Series User's Manual (Cat. No. Z337)
• 2D-code
Reading 2D-codes in FQ2-S/CH Series User's Manual (Cat. No. Z337)
• 2D-code (DPM)
Reading 2D codes (DPM) in FQ2-S/CH Series User's Manual (Cat. No. Z337)
The procedure for outputting the character string is given here with PLC Link communications.
[In/Out] − [I/O setting] − [Output data set] − [Link data output/Fieldbus data output] − [Output
data set]
1
Select the inspection item for which to output the character string.
2
Set the following items on the setting display.
FQ2-S/CH User's Manual
for Communications Settings
Description
Controlling Operation and Outputting Data with PLC Link Communications
Setting range
Floating point or fixed point (default: fixed point)
131