Omron FQ2-S/CH Series User Manual page 60

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Executing External Teaching
Teaching for all registered items can be executed using the current input image.
Note
• This command is only valid in Expanded Mode.
• Application is possibly only from the Run Mode
• If the parameter is applicable to more than one inspection item, it will be external teaching for all inspection items.
Wiring
Color
Signal
Gray
IN0
Green
IN1
Red
IN2
White
IN3
Purple
IN4
Yellow
IN5
Orange
OUT1 (BUSY)
Timing Chart
IN0 to IN4 signals
ON
IN5 signal
OFF
ON
BUSY signal
OFF
58
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
State
Description
ON
OFF
OFF
Command parameter for external teaching
ON
OFF
ON
Command input for external teaching
--
Processing in progress (default)
Allow 5 ms min. and then
turn ON IN5.
ON for 1 ms min.
Start external teaching
End external teaching
The signals shown at the left are
used.
Refer to the following information
for signal wiring.
Section 2 Installation and
Connections
in Sensor FQ2-S/CH Series
User's Manual
(Cat. No. Z337)
1Turn ON IN0 and IN3 and turn OFF IN1,
IN2, and IN4.
2Turn ON the IN5 signal while the BUSY
signal is OFF to execute external
teaching.
3The BUSY signal turns ON while
external teaching is being executed.
FQ2-S/CH User's Manual
for Communications Settings